On LED keypads, Press the *2,
yellow light flashes and a number 1 thru 8 will come up on the display.

Light 1, Service required, press key 1 for more details,
if number 1 light stays on, the main battery backup needs replacing.
If number 2 thru 8 comes on call for service.

Light 2, Power Off to alarm panel, (power off, breaker off, transformer bad or unplugged).

Light 3, Telephone Line Trouble, no phone line working on the alarm system phone jack.

Light 4, Failure to Communicate, on the last alarm the system could not make a call to
the monitoring station, (this will only clear off after a successful alarm communication to
the monitoring station).

Light 5, Zone Fault, press key 5 for more details, the zone light with fault will come on.
A wireless device has not checked in, smoke detector etc.

Light 6, Zone Tamper, press key 6 for more details, the zone with the tamper condition
will come on. A wireless device has a cover not on, check the device cover.

Light 7, Wireless Device Low Battery, press key 7 for more details, the zone/s with a bad
battery will come on, replace the zone device battery, then open door/window should
clear this trouble.

Light 8, Loss of Clock, the main panel internal clock is not set, (set the clock).
To Set Clock: press * ,6, main code, 1, enter time and date (HH:MM MM/DD/YY),  # to exit.